From: Sergei Shtylyov <sergei.shtyl...@cogentembedded.com>
Date: Thu, 04 Jan 2018 21:06:49 +0300

> Renesas  SH7757 has 2 Fast and 2 Gigabit Ether controllers, while the
> 'sh_eth' driver can only reset and initialize TSU of the first controller
> pair. Shimoda-san tried to solve that adding the 'needs_init' member to the
> 'struct sh_eth_plat_data', however the platform code still never sets this
> flag. I think  that we can infer this information from the 'devno' variable
> (set  to 'platform_device::id') and reset/init the Ether controller pair
> only for an even 'devno'; therefore 'sh_eth_plat_data::needs_init' can be
> removed...
> 
> Fixes: 150647fb2c31 ("net: sh_eth: change the condition of initialization")
> Signed-off-by: Sergei Shtylyov <sergei.shtyl...@cogentembedded.com>

Applied and queued up for -stable.