Document r8a7744 specific compatible strings. No driver change is
needed as the fallback compatible string "renesas,tpu" activates the
right code in the driver.

Signed-off-by: Biju Das <biju....@bp.renesas.com>
Reviewed-by: Chris Paterson <chris.paters...@renesas.com>
---
This patch is tested against next-20181004
---
 Documentation/devicetree/bindings/pwm/renesas,tpu-pwm.txt | 1 +
 1 file changed, 1 insertion(+)

diff --git a/Documentation/devicetree/bindings/pwm/renesas,tpu-pwm.txt 
b/Documentation/devicetree/bindings/pwm/renesas,tpu-pwm.txt
index d53a167..6d6f680 100644
--- a/Documentation/devicetree/bindings/pwm/renesas,tpu-pwm.txt
+++ b/Documentation/devicetree/bindings/pwm/renesas,tpu-pwm.txt
@@ -6,6 +6,7 @@ Required Properties:
     - "renesas,tpu-r8a73a4": for R8A73A4 (R-Mobile APE6) compatible PWM 
controller.
     - "renesas,tpu-r8a7740": for R8A7740 (R-Mobile A1) compatible PWM 
controller.
     - "renesas,tpu-r8a7743": for R8A7743 (RZ/G1M) compatible PWM controller.
+    - "renesas,tpu-r8a7744": for R8A7744 (RZ/G1N) compatible PWM controller.
     - "renesas,tpu-r8a7745": for R8A7745 (RZ/G1E) compatible PWM controller.
     - "renesas,tpu-r8a7790": for R8A7790 (R-Car H2) compatible PWM controller.
     - "renesas,tpu": for generic R-Car and RZ/G1 TPU PWM controller.
-- 
2.7.4