On 04/16/2015 03:46 PM, Don Brace wrote:
> From: Webb Scales <web...@hp.com>
>
> We had a mix of formats used for specifying controller, bus, target,
> and lun address of devices.
>
> change to the format used by the scsi midlayer and upper layer (2:3:0:0)
> so you can easily follow the information from hpsa to scsi midlayer
> to sd upper layer.
>
> Also add this information:
> - product ID
> - vendor ID
> - RAID level
> - SSD Smath Path capable and enabled
> - exposure level (sg-only)
>
> Example:
> hpsa 0000:04:00.0: added scsi 2:0:0:0: Direct-Access     HP LOGICAL VOLUME   
> RAID-0 SSDSmartPathCap+ En+ Exp=4
> scsi 2:0:0:0: Direct-Access     HP       LOGICAL VOLUME   10.0 PQ: 0 ANSI: 5
> sd 2:0:0:0: [sdr] 12501713072 512-byte logical blocks: (6.40 TB/5.82 TiB)
> sd 2:0:0:0: [sdr] 4096-byte physical blocks
> sd 2:0:0:0: [sdr] Attached SCSI disk
> sd 2:0:0:0: Attached scsi generic sg20 type 0
>
> Reviewed-by: Scott Teel <scott.t...@pmcs.com>
> Reviewed-by: Kevin Barnett <kevin.barn...@pmcs.com>
> Signed-off-by: Robert Elliott <elli...@hp.com>
> Signed-off-by: Don Brace <don.br...@pmcs.com>

Reviewed-by: Tomas Henzl <the...@redhat.com>

Tomas

--
To unsubscribe from this list: send the line "unsubscribe linux-scsi" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html

Reply via email to