From: Hannes Reinecke <h...@suse.com>

The bus reset function is a subset of host reset, but will always
return SUCCESS. But as the host reset also invokes a reset for
all ports there is a possibility that the bus reset will not be
able to fully reset the HBA, leading to a blocked system.
So drop bus reset completely.

Signed-off-by: Hannes Reinecke <h...@suse.com>
---
 drivers/scsi/aha152x.c | 10 ----------
 1 file changed, 10 deletions(-)

diff --git a/drivers/scsi/aha152x.c b/drivers/scsi/aha152x.c
index ce5dc73..21e9d7c 100644
--- a/drivers/scsi/aha152x.c
+++ b/drivers/scsi/aha152x.c
@@ -1165,15 +1165,6 @@ static int aha152x_bus_reset_host(struct Scsi_Host 
*shpnt)
 }
 
 /*
- * Reset the bus
- *
- */
-static int aha152x_bus_reset(Scsi_Cmnd *SCpnt)
-{
-       return aha152x_bus_reset_host(SCpnt->device->host);
-}
-
-/*
  *  Restore default values to the AIC-6260 registers and reset the fifos
  *
  */
@@ -2916,7 +2907,6 @@ static int aha152x_adjust_queue(struct scsi_device 
*device)
        .queuecommand                   = aha152x_queue,
        .eh_abort_handler               = aha152x_abort,
        .eh_device_reset_handler        = aha152x_device_reset,
-       .eh_bus_reset_handler           = aha152x_bus_reset,
        .eh_host_reset_handler          = aha152x_host_reset,
        .bios_param                     = aha152x_biosparam,
        .can_queue                      = 1,
-- 
1.8.5.6