On 6 Mar 2000, Matthias Andree wrote:

> short: Tandberg TDC4222 does not do sync transfers on Tekram DC-390U
> (SYM53C875)
> 
> 
> 
> setup: 
> Linux 2.2.14 (openwall, reiserfs, current ide driver patches)
> 
> Tekram DC-390U with BIOS 3.20, drives as shown below, Plextor PX-32 is
> terminated at bus cable end, host adaptor is supposed to be terminated
> as well. 


[ ... ]

> problem:
> 
> Now, during the BIOS bus scan, the Tekram reports the Tandberg tape
> drive as offset 8 Byte/Handshake, 4 MXfers/s synchronous, in conformance
> with the Tandberg documentation. Loading the st module (2.2.14) 

[ ... ]

> sym53c875-0-<6,*>: target did not report SYNC.
> 
> Why does the Tekram BIOS report the Tandberg drive as 4 MB/s while the
> SYM driver reports the drive as using async? The sym driver is at its
> default settings (or does it read ncr53c8xx=tags:32,debug:0x200,specf:1?)
> 
> Is this the driver's or the drive's fault? Is it that the max sync xfer
> rate is only 4 MB/s? How do I track this problem down to is root?
> 
> How do I fix this?

A nail and a hammer would not help:), but result from 'scsiinfo -i' can.
Let me know.

Gerard.



-
To unsubscribe from this list: send the line "unsubscribe linux-scsi" in
the body of a message to [EMAIL PROTECTED]

Reply via email to