Hi rekan-rekan, Setelah dicek ternyata masalahnya ada di modemku nih. (kayaknya) Saya coba switch modemnya yg di com1 ke com2 dan sebaliknya. Hasilnya: dengan modem rockwell yang lama bisa jalan dengan mulus tapi dengan modem prolink (chipset Intel Md56xxx) nggak mau. Apakah mungkin karena init chat yang berbeda?
Begini perbandingan log dari ttyS0 (Prolink) dab ttyS1(Rockwell) 06/26 10:07:05 yS0 waiting... 06/26 10:07:31 yS0 select returned 1 06/26 10:07:31 yS0 checking lockfiles, locking the line 06/26 10:07:31 yS0 makelock(ttyS0) called 06/26 10:07:31 yS0 do_makelock: lock='/var/lock/LCK..ttyS0' 06/26 10:07:31 yS0 lock made 06/26 10:07:31 yS0 wfr: waiting for ``RING'' 06/26 10:07:31 yS0 got: [0d][0a]RING[0d] 06/26 10:07:31 yS0 CND: RING 06/26 10:07:31 yS0 wfr: rc=0, drn=0 06/26 10:07:31 yS0 CND: check no: 'none' 06/26 10:07:31 yS0 send: ATA[0d] 06/26 10:07:31 yS0 waiting for ``CONNECT'' 06/26 10:07:31 yS0 got: ATA[0d] 06/26 10:07:31 yS0 CND: OKATA[0d][0a]NO CARRIER 06/26 10:07:46 yS0 found action string: ``NO CARRIER'' 06/26 10:07:46 ##### failed A_FAIL dev=ttyS0, pid=24458, caller='none', conn='', name='' 06/26 10:07:04 yS1 waiting... 06/26 10:08:12 yS1 select returned 1 06/26 10:08:12 yS1 checking lockfiles, locking the line 06/26 10:08:12 yS1 makelock(ttyS1) called 06/26 10:08:12 yS1 do_makelock: lock='/var/lock/LCK..ttyS1' 06/26 10:08:12 yS1 lock made 06/26 10:08:12 yS1 wfr: waiting for ``RING'' 06/26 10:08:12 yS1 got: [0d][0a]RING[0d] 06/26 10:08:12 yS1 CND: RING 06/26 10:08:12 yS1 wfr: rc=0, drn=0 06/26 10:08:12 yS1 CND: check no: 'none' 06/26 10:08:12 yS1 send: ATA[0d] 06/26 10:08:12 yS1 waiting for ``CONNECT'' 06/26 10:08:12 yS1 got: ATA[0d] 06/26 10:08:12 yS1 CND: OKATA[0d][0a]COMPRESSION: V.42BIS[0d] 06/26 10:08:31 yS1 CND: COMPRESSION: V.42BIS[0a][0d][0a]CONNECT ** found ** 06/26 10:08:31 yS1 send: 06/26 10:08:31 yS1 waiting for ``_'' 06/26 10:08:31 yS1 got: 38400[0d] 06/26 10:08:31 yS1 CND: CONNECT 38400 06/26 10:08:31 yS1 CND: found: 38400[0a] ** found ** Yang paling menonjol ada di setelah baris 06/26 10:08:12 yS1 waiting for ``CONNECT'' 06/26 10:08:12 yS1 got: ATA[0d] yg prolink send 06/26 10:07:31 yS0 CND: OKATA[0d][0a]NO CARRIER yg rockwell send 06/26 10:08:12 yS1 CND: OKATA[0d][0a]COMPRESSION: V.42BIS[0d] Any clue? Apakah ini berarti modemnya nggak bisa dipake untuk dialin?? Atau bisa di program ulang dengan AT command di modem?? Pls help.. -- Best regards, Romie Djapri --------------------------------------------------------------------- To unsubscribe, e-mail: [EMAIL PROTECTED] For additional commands, e-mail: [EMAIL PROTECTED]