I can't remember the way to reproduce this right now... the drugs are
getting in the way...  however, I can say that I unlink the URB by calling
usb_release_irq() when I get the disconnect callback.

There are basically 3 possibilities for reproducing:

(1) Load all drivers, attach a device, and remove the device
(2) Load all drivers, attach a device, then remove the HCD
(3) Load all drivers, attach a device, then remove usb-storage

This presumes that you have a CBI device (such as a Y-E Data floppy
drive).  You don't have to access the device to see this behavior.  The
latest patch I sent to the list includes debugging output to show what's
happening and all the relevant values in dmesg

Matt Dharm

On Thu, 6 Apr 2000, Johannes Erdfelt wrote:

> > I'm not sure Matt said it was _after_ that ... though I didn't
> > quite see a complete "how to reproduce this" scenario.
> 
> I was explaining the two situations that could possibly occur given
> Matthew's original explanation:
> 

-- 
Matthew Dharm                              Home: [EMAIL PROTECTED] 
Engineer, Qualcomm, Inc.                         Work: [EMAIL PROTECTED]

Sir, for the hundreth time, we do NOT carry 600-round boxes of belt-fed 
suction darts!
                                        -- Salesperson to Greg
User Friendly, 12/30/1997


---------------------------------------------------------------------
To unsubscribe, e-mail: [EMAIL PROTECTED]
For additional commands, e-mail: [EMAIL PROTECTED]

Reply via email to