On Fri, 22 Mar 2019, Tony Lindgren wrote:

> * Alan Stern <[email protected]> [190322 18:37]:
> > How about putting these runtime PM additions into
> > usb_hcd_platform_shutdown instead, so they will apply to all platform
> > controller drivers?
> 
> OK let's do that then.
> 
> > Also, are you certain you want the pm_runtime_put_sync at the end?  If 
> > the system is shutting down anyway, why waste time doing an extra 
> > runtime suspend?
> 
> Well mostly to keep the calls paired. But maybe there are
> also kexec reboot cases where we'd want to have things
> properly disabled for PM before kexec.

I'm not sure that makes sense.  You can't actually disable anything for 
runtime PM from within a driver; all you can do is tell the runtime PM 
core that _you're_ not using the device any more.  But if some other 
part of the system is still using it, it will remain at full power.

Alan Stern