From: Mahesh Salgaonkar <mah...@linux.vnet.ibm.com>

On some CAPP errors we see console messages that prints unknown HMIs for
which CAPI recovery is in progress. This patch fixes this by printing
correct error info for HMI generated due to CAPP recovery.

Signed-off-by: Mahesh Salgaonkar <mah...@linux.vnet.ibm.com>
Tested-by: Andrew Donnellan <andrew.donnel...@au1.ibm.com>
---
 arch/powerpc/platforms/powernv/opal-hmi.c |    3 ++-
 1 file changed, 2 insertions(+), 1 deletion(-)

diff --git a/arch/powerpc/platforms/powernv/opal-hmi.c 
b/arch/powerpc/platforms/powernv/opal-hmi.c
index c0a8201..0d0d5f7 100644
--- a/arch/powerpc/platforms/powernv/opal-hmi.c
+++ b/arch/powerpc/platforms/powernv/opal-hmi.c
@@ -180,7 +180,8 @@ static void print_hmi_event_info(struct OpalHMIEvent 
*hmi_evt)
                "An XSCOM operation completed",
                "SCOM has set a reserved FIR bit to cause recovery",
                "Debug trigger has set a reserved FIR bit to cause recovery",
-               "A hypervisor resource error occurred"
+               "A hypervisor resource error occurred",
+               "CAPP recovery process is in progress"
        };
 
        /* Print things out */

Reply via email to