On Fri, 18 Oct 2024 07:07:30 +0100, Ed Robbins wrote:
> If the power supply type is not set it defaults to "Unknown" and upower
> does not recognise it. In turn battery monitor applications do not see a
> battery. Setting to POWER_SUPPLY_TYPE_BATTERY fixes this.
> 
> 

Applied, thanks!

[1/1] pmu_battery: Set power supply type to BATTERY
      commit: 3287673c1d26f94845ef958090c583c46054b70d

Best regards,
-- 
Sebastian Reichel <[email protected]>