TSEC/MDIO will not work with older device trees because of a semicolon
at the end of a macro resulting in an empty for loop body.
This fix only applies to 2.6.28; this code is gone in 2.6.29, according
to Grant Likely!
Signed-off-by: Johns Daniel <johns.dan...@gmail.com
<mailto:johns.dan...@gmail.com>>
======================================
--- linux-2.6.28.7/arch/powerpc/sysdev/fsl_soc.c.orig 2009-02-20
16:41:27.000000000 -0600
+++ linux-2.6.28.7/arch/powerpc/sysdev/fsl_soc.c 2009-03-14
09:01:38.994630400 -0500
@@ -257,7 +257,7 @@ static int __init gfar_mdio_of_init(void
gfar_mdio_of_init_one(np);
/* try the deprecated version */
- for_each_compatible_node(np, "mdio", "gianfar");
+ for_each_compatible_node(np, "mdio", "gianfar")
gfar_mdio_of_init_one(np);
return 0;
_______________________________________________
Linuxppc-dev mailing list
Linuxppc-dev@ozlabs.org