On Thu, 31 Mar 2011, Benjamin Herrenschmidt wrote:

> On Wed, 2011-03-30 at 14:36 -0400, Eric B Munson wrote:
> > On Wed, 30 Mar 2011, Benjamin Herrenschmidt wrote:
> > 
> > > On Tue, 2011-03-29 at 10:25 -0400, Eric B Munson wrote:
> > > > Here I made the assumption that the hardware would never remove more 
> > > > events in
> > > > a speculative roll back than it had added.  This is not a situation I
> > > > encoutered in my limited testing, so I didn't think underflow was 
> > > > possible.  I
> > > > will send out a V2 using the signed 32 bit delta and remeber to CC 
> > > > stable
> > > > this time. 
> > > 
> > > I'm not thinking about underflow but rollover... or that isn't possible
> > > with those counters ? IE. They don't wrap back to 0 after hitting
> > > ffffffff ?
> > > 
> > 
> > They do roll over to 0 after ffffffff, but I thought that case was already
> > covered by the perf_event_interrupt.  Are you concerned that we will reset a
> > counter and speculative roll back will underflow that counter?
> 
> No, but take this part of the patch:
> 
> > --- a/arch/powerpc/kernel/perf_event.c
> > +++ b/arch/powerpc/kernel/perf_event.c
> > @@ -416,6 +416,15 @@ static void power_pmu_read(struct perf_event *event)
> >             prev = local64_read(&event->hw.prev_count);
> >             barrier();
> >             val = read_pmc(event->hw.idx);
> > +           /*
> > +            * POWER7 can roll back counter values, if the new value is
> > +            * smaller than the previous value it will cause the delta
> > +            * and the counter to have bogus values.  If this is the
> > +            * case skip updating anything until the counter grows again.
> > +            * This can lead to a small lack of precision in the counters.
> > +            */
> > +           if (val < prev)
> > +                   return;
> >     } while (local64_cmpxchg(&event->hw.prev_count, prev, val) != prev);
> 
> Doesn't that mean that power_pmu_read() can only ever increase the value of
> the perf_event and so will essentially -stop- once the counter rolls over ?
> 
> Similar comments every where you do this type of comparison.
> 
> Cheers,
> Ben.

Sorry for the nag, but am I missing something about the way the register and
the previous values are reset in the overflow interrupt handler?

Thanks,
Eric

Attachment: signature.asc
Description: Digital signature

_______________________________________________
Linuxppc-dev mailing list
Linuxppc-dev@lists.ozlabs.org
https://lists.ozlabs.org/listinfo/linuxppc-dev

Reply via email to