On Fri, Mar 12, 2021 at 01:25:21PM +0000, Wischer Timo (XC-CI1/EPC1-E) wrote:
> Hello Richard,
>
> at least for me the specification is quite confusing at this point.
>
> Chapter "10.5.4.1 General Signaling message specifications" of
> IEEE8021AS-2011 describes
> targetPortIdentity with a size of 10 octets.
Look at the 2020 edition. There it is crystal clear.
10.6.4.2 Signaling message field specifications
10.6.4.2.1 targetPortIdentity (PortIdentity)
The value of targetPortIdentity.clock identity is all ones, i.e.,
0xFFFFFFFFFFFFFFFF. The value of targetPortIdentity.portNumber is
all ones, i.e., 0xFFFF.
-- IEEE Std 802.1AS-2020, page 150