On Thu, Mar 16, 2023 at 02:58:33PM +0100, Andrew Zaborowski wrote:

> I was now made aware that Avnu conformance tests for 802.1AS-2011 do
> validate the 3 different values required in the control field in that
> version of IEEE802.1AS.  While 1588-2008 did already say that the use
> of this field on the receiver is "deprecated", 802.1AS-2011 does not
> say anything like this.  There's value for Avnu in having an option to
> go back to those values and perhaps shipping a "gPTP-2011.cfg" file
> with that option enabled.  Would you be open to have this upstream?

That was twelve years ago.  We needn't take such an overly pedantic
test seriously.  I'll just update the home page to say, "supports
802.1AS-2020".

Thanks,
Richard


_______________________________________________
Linuxptp-devel mailing list
Linuxptp-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/linuxptp-devel

Reply via email to