On Tue, Aug 06, 2019 at 12:58:11PM +0530, Alexander Sylvester wrote:
> HI Miroslav,
> 
> So are you saying that each time I connect my Slave node, I have to make
> sure that my GM is running already and if I do so  ptp4l should be able
> to make a step on the first update of the clock and reach synchronization
> much faster? Is my understanding correct?

Yes. It's one way to get your requirements. ptp4l by default allows
one step on the first update. I think you either need to make sure the
first update is from the intended GM and not some random clock that
happens to be the GM before the real one is running, or allow multiple
steps, assuming that's really the problem you are hitting.

-- 
Miroslav Lichvar