Hello there,
My network are a LS1021ATSN platform and two boards connected to it.
802.1AS is the standard used.
When I set the time on the ptp1 phc clock of the LS1021ATSN and I run
ptp4l and phc2sys on the LS1021ATSN platform and the boards, I can see
that I have two more hours on the boards than the platform. Is it due to
the GMT+2 or something like that? Does it influence on the correct
functionality of the synchroniztion of time?
These are the instructions used.
LS1021ATSN:
phc_ctl /dev/ptp1 set 1612270628.000000000 && phc_ctl /dev/ptp1 freq 0
ptp4l -i swp2 -i swp3 -f /etc/ptp4l_cfg/gPTP.cfg --tx_timestamp_timeout
20 --step_threshold 0.0 --first_step_threshold 0.00002
NODES:
phc_ctl /dev/ptp0 freq 0
ptp4l -i enp3s0 -f /etc/ptp4l_cfg/gPTP.cfg --tx_timestamp_timeout 20
--step_threshold 0.0 --first_step_threshold 0.00002
phc2sys -a -rr --transportSpecific 0x1 --step_threshold 0.0
--first_step_threshold 0.00002
Thank you very much.
Diego
_______________________________________________
Linuxptp-users mailing list
Linuxptp-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/linuxptp-users