Acked-by: Ping Cheng <[email protected]> Both the attached patch below and the man page patch of this thread look good to me. I know my comment below is outside of the two patches that we are talking about, I'd still like to bring it up one more time so someone may fix the issue in the server.
With the following line: > + nbbuttons = (nbbuttons > 3) ? nbbuttons + 4 : 7; we will not be able to send a button event larger than 7 for a device has less than 4 buttons and nbbuttons + 4 for a device has less than nbbuttons+1 buttons. This is not "nice". I think the X server needs to have a separate entity to store the maximum number of server supported button events. The number of physical buttons of a device supports has nothing to do with which button events the physical button can post. Ping ------------------------------------------------------------------------------ Download Intel® Parallel Studio Eval Try the new software tools for yourself. Speed compiling, find bugs proactively, and fine-tune applications for parallel performance. See why Intel Parallel Studio got high marks during beta. http://p.sf.net/sfu/intel-sw-dev _______________________________________________ Linuxwacom-devel mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/linuxwacom-devel