can you paste in the configuration file that Chainsaw is using? I wonder if you have it using the XMLLayout for the file appender.

On 13/06/2007, at 5:37 AM, ashish talati wrote:

Hi Scott,
  Thank you very much for your help.
  Its working now.
  Moreover
1)-> I am trying to load this file again into chainsaw through Drag and Drop XML file option, but nothing is happened. that option keeps disable all time. Can you please tell me what is the problem??
  I saved my file as .xml
  and
2)-> how I can use the filed NDC,class,method,line???? right now all are null. I want to use these field to differentiate between the log sources it is coming from.
        do you have any idea how I can do that?

  Thanks.


Scott Deboy <[EMAIL PROTECTED]> wrote:
  Add an appender-ref entry to the root node:






Scott Deboy
Principal Engineer
COMOTIV SYSTEMS
111 SW Columbia Street Ste. 950
Portland, OR 97201
Office: 503.224.7496
Direct Line: 503.821.6482
Cell: 503.997.1367
Fax: 503.222.0185
[EMAIL PROTECTED]
www.comotivsystems.com

-----Original Message-----
From: ashish talati [mailto:[EMAIL PROTECTED]
Sent: Tuesday, June 12, 2007 10:59 AM
To: [email protected]
Subject: chainsaw configuration help

Hi scott,
thank you very much for reply.
I did use the file appender in my chainsaw receiver configuration as
below,



debug="true">

class="org.apache.log4j.RollingFileAppender">


















class="org.apache.log4j.net.SocketReceiver">














It is creating chainsaw file in the C drive but nothing comes in
there.
Please let me know where I did wrong in this??

Thanks.



---------------------------------
TV dinner still cooling?
Check out "Tonight's Picks" on Yahoo! TV.

---------------------------------------------------------------------
To unsubscribe, e-mail: [EMAIL PROTECTED]
For additional commands, e-mail: [EMAIL PROTECTED]




---------------------------------
Park yourself in front of a world of choices in alternative vehicles.
Visit the Yahoo! Auto Green Center.

Paul Smith
Core Engineering Manager

Aconex
The easy way to save time and money on your project

696 Bourke Street, Melbourne,
VIC 3000, Australia
Tel: +61 3 9240 0200  Fax: +61 3 9240 0299
Email: [EMAIL PROTECTED]  www.aconex.com

This email and any attachments are intended solely for the addressee. The contents may be privileged, confidential and/or subject to copyright or other applicable law. No confidentiality or privilege is lost by an erroneous transmission. If you have received this e-mail in error, please let us know by reply e-mail and delete or destroy this mail and all copies. If you are not the intended recipient of this message you must not disseminate, copy or take any action in reliance on it. The sender takes no responsibility for the effect of this message upon the recipient's computer system.



Reply via email to