What happens if you remove the <Assembly:
log4net.Config.XmlConfigurator()> attribute and add a call to
log4net.Config.XmlConfigurator() after the call to
RemotingConfiguration.Configure();

Nicko

> -----Original Message-----
> From: Xavier Terrier [mailto:[EMAIL PROTECTED] 
> Sent: 06 November 2005 13:46
> To: [email protected]
> Subject: Remoting appender in a Remoting application
> 
> Hi,
> 
> Has anyone any idea to resolve this problem,
> 
> I tried to use a remoting appender like this :
> <appender name="RemotingAppender" 
> type="log4net.Appender.RemotingAppender" >
>        <sink value="tcp://localhost:8085/LoggingSink" />
>        <lossy value="false" />
>        <bufferSize value="95" />
>        <onlyFixPartialEventData value="true" /> </appender>
> 
> in an application which run itself a Remoting (which has 
> nothing to do with the log4net Remoting). The logger with the 
> remoting appender goes well but the Remoting of the app can't 
> be initialize (Exception : Tcp channel already registered)
> 
> Here the code of the app :
> Imports log4net
> Imports System.Runtime.Remoting
> 
> 'Configure log4net using the .config file
> <Assembly: log4net.Config.XmlConfigurator()>
> 
> Module Module1
> 
> ' If this log Object have a remoting appender, 
> RemotingConfiguration.Configure... will fail
>      Private ReadOnly log As log4net.ILog = 
> log4net.LogManager.GetLogger(System.Refl
> ection.MethodBase.GetCurrentMethod().DeclaringType)
> 
>      Sub Main()
>          Try           
> RemotingConfiguration.Configure(AppDomain.CurrentDomain.SetupI
> nformatio
> n.ConfigurationFile)
>          Catch ex As Exception
>              Throw ex
>          End Try
>      End Sub
> 
> End Module
> 
> 
> 
> 

Reply via email to