On Wed, 2008-11-05 at 22:25 +0100, Nicklas Bondesson wrote: > I also noticed that it was only the vrrp instances (vips) bound to a certain > nic that transitioned to master on the backup node. Could it be a buggy > driver or faulty hw? The nic is an onboard via velocity gigabit card. We > have three nics in each firewall and the other two are Intel cards.
Ah. It could well be that something in the power outage - a spike or surge - has caused a NIC to fail. Can you try it on a different adapter? Graeme _______________________________________________ LinuxVirtualServer.org mailing list - [email protected] Send requests to [EMAIL PROTECTED] or go to http://lists.graemef.net/mailman/listinfo/lvs-users