In a recent note, [EMAIL PROTECTED] said:
> Date: Fri, 9 Feb 2001 09:09:17 -0700 (MST)
>
> Lynx now exiting with signal: 11
> SunOS sanitas 5.6 Generic_105181-13 sun4u sparc SUNW,Ultra-5_10
>
> LYReadCmdKey(0) ->= (0x3d)
>
Similarly broken on OS/390:
Lynx now exiting with signal: 11
CEE5207E The signal SIGABRT was received.
[2] + Done(131) ./lynx
50331751 Abort ./lynx
SPPG@MVS3:155$ uname -a
OS/390 MVS3 07.00 02 9672
> Early warning. I'll analyze the dump later. Last time I had this, a NULL
> was being passed to a Curses routine. Slang and Ncurses tolerated it;
> Old Curses got a SIGSEGV.
>
What I was thinking of was:
2000-08-03 (2.8.4dev.7)
* correct logic in LYsubwindow(), which called delwin() with a null WINDOW
pointer -PG, TD
Linkname: Re: lynx-dev <select></select> problem
URL: http://www.flora.org/lynx-dev/html/month082000/msg00017.html
> File that you are currently viewing
> Linkname: Re: lynx-dev Crash in popup menu
> URL: http://www.flora.org/lynx-dev/html/month072000/msg00271.html
-- not a very close match. I'll investigate further.
-- gil
--
StorageTek
INFORMATION made POWERFUL
; To UNSUBSCRIBE: Send "unsubscribe lynx-dev" to [EMAIL PROTECTED]