Hi MARSS uses the system frequency as corefreq by default. Did you set the corefreq in your simconfig ? if not please set it up and let us know if that solve the problem -Furat
On Thu, Jun 14, 2012 at 9:24 AM, Addison Mayberry <[email protected]>wrote: > Greetings, > I'm taking some measurements on an image without using checkpoints - I > have it set up so that when the image is run and boots, it immediately logs > in to root, drops into simulation, and runs my benchmark. I've noticed > that, when I do this on different machines, the total cycle count (as seen > in stats.yaml and reading the sim_cycle variable) over the course of > simulation varies fairly dramatically depending on which machine it's on. > Since cycles elapsed affects some of my measurements, I'd like to have the > experiment be repeatable across different machines, and have some assurance > that the cycle count I'm seeing is at least relatively accurate, if > possible. Is this variation expected, due to the way MARSS is set up? > > Thanks in advance. > Sincerely, > Addison > > ______________________________**_________________ > http://www.marss86.org > Marss86-Devel mailing list > [email protected].**edu <[email protected]> > https://www.cs.binghamton.edu/**mailman/listinfo/marss86-devel<https://www.cs.binghamton.edu/mailman/listinfo/marss86-devel> >
_______________________________________________ http://www.marss86.org Marss86-Devel mailing list [email protected] https://www.cs.binghamton.edu/mailman/listinfo/marss86-devel