As Dr. Zimmerman has said at least one generator is required at slack bus to run load flow, one can assume the substation bus where power is incoming as slack bus and place an equivelent generator at that bus to run distribution load flow.
Best of Luck. Kanwardeep Singh On Tue, 06 Oct 2009 21:45:28 +0530 wrote >You will need at least a single generator at the slack bus. --Ray ZimmermanSenior Research Associate211 Warren Hall, Cornell University, Ithaca, NY 14853phone: (607) 255-9645 On Oct 6, 2009, at 1:54 AM, Kanishk Chaudhary wrote:On Tue, Oct 6, 2009 at 11:11 AM, Neeraj Gupta wrote: ok tell me what level of knowledge you have. Kanishk Chaudhary > sir, > please guid me regarding how to run radial distribution load flow by > mat > power. > > Kanishk Chaudhary > BTech electrical final student > IET lucknow(indian) > -- ************************* Neeraj Gupta Research Scholar, P&C(EE) Y6104097 IIT Kanpur ************************ Sir,i m final year EE student doing project on capacitor placement on radial distribution system. i m tying to run load flow on matpower on default newton PF. I took data from Baran n wu reconfiguration 32 us data ......there is problem while running the load flow as data priscibe as in case9 is not same what i put for 32bus data....as what i take bus one as slake bus remaining PQ bus .....the runpf is having error because there is no generator data in what i enter there is only BUS AND LINE data....so please sir help to this problem. Kanishk Btech 4th year EE studentIET lucknow