Thanks a lot Dr.Ray,

Indeed,  i made a printing mistake while i was writing an email, the
meaning of [reluctance] is (reactance*) is referring to branch reactance.

But the one thing that i would know is , when i change the values of
reactance what i will get, Do i have to implement the same code?, an
example(0,0.01,0.02,0.03....1) which the changes should be incremental.

 Best wishes.

On 28 February 2017 at 20:47, Ray Zimmerman <[email protected]> wrote:

> [image: Boxbe] <https://www.boxbe.com/overview> This message is eligible
> for Automatic Cleanup! ([email protected]) Add cleanup rule
> <https://www.boxbe.com/popup?url=https%3A%2F%2Fwww.boxbe.com%2Fcleanup%3Fkey%3DSy8C1rcnbw%252Ft1f1GMSd9Q2UQ7DPgfvMwQB4x%252BB94c7E%253D%26token%3DDlar1G6Phas%252Bn1AXRB3YxbrynIOm5%252BvF5%252FjAOuZnL%252BtFJ%252FGcNkuDe79c97wrql1McjU8eD01W3hfR9zNO0mf44ITNZxlSUmHe8buDR1J8hZk%252F1%252Bn1Vu2IldXkrqCwNFQ7fHI1zd43TA%253D&tc_serial=29102031072&tc_rand=1966739810&utm_source=stf&utm_medium=email&utm_campaign=ANNO_CLEANUP_ADD&utm_content=001>
> | More info
> <http://blog.boxbe.com/general/boxbe-automatic-cleanup?tc_serial=29102031072&tc_rand=1966739810&utm_source=stf&utm_medium=email&utm_campaign=ANNO_CLEANUP_ADD&utm_content=001>
>
> I’m not sure what you mean by “reluctance voltage” and “reactance
> voltage”, but if you are referring to the branch reactance, then setting it
> to zero causes the Ybus matrix to become singular and the power flow fails.
> See the example below.
>
>     Ray
>
>
> >> define_constants
> >> mpc = loadcase('case14');
> >> mpopt = mpoption('out.all', 0);
> >> r = runpf(mpc, mpopt);
>
> MATPOWER Version 6.1-dev, 21-Feb-2017 -- AC Power Flow (Newton)
>
> Newton's method power flow converged in 2 iterations.
> >> sum(real(get_losses(r)))
>
> ans =
>
>    13.3933
>
> >> mpc.branch(14, BR_X) = 1e-5;
> >> r = runpf(mpc, mpopt);
>
> MATPOWER Version 6.1-dev, 21-Feb-2017 -- AC Power Flow (Newton)
>
> Newton's method power flow converged in 4 iterations.
> >> sum(real(get_losses(r)))
>
> ans =
>
>    13.4047
>
> >> mpc.branch(14, BR_X) = 0;
> >> r = runpf(mpc, mpopt);
>
> MATPOWER Version 6.1-dev, 21-Feb-2017 -- AC Power Flow (Newton)
>
> Newton's method power flow did not converge in 10 iterations.
> >> sum(real(get_losses(r)))
>
> ans =
>
>    NaN
>
>
>
> On Feb 28, 2017, at 12:07 PM, Abdulgader Alsharif <
> [email protected]> wrote:
>
> Dear all
>
> I am Master student and a new in MATPOWER, using Matpower to find the
> losses in transmission lines (runpf) and how to change the reluctance
> voltage value in case14 as an example.
>
> Also, to find the daily PV load profile.
>
> Could you please help in writing Matlab code that change the reactance
> voltage values.
>
> I have tried with one but cannot working..
>
> NOTE:
> (r.branch(14,4)=0)
> when (14,4) is the position of the reactance value that i want to change,
> (0) is the initial changes will be incrementally.
>
> CODE
> for reactance (i) = Branchdata
>     r.branch(14,4)=0
> end
>
>
> ​Already appreciated ..thanks to all​
>
> --
> ABDULGADER H. ABDULGADER ALSHARIF
> MASTER STUDENT AT ISTANBUL KEMERBURGAZ UNIVERSITY
> LIVE IN ISTANBUL-TURKEY
> Mobile phone Viber & whatsapp no. 00905454567238 <0545%20456%2072%2038>.
> Skype: [email protected]
>
>
>
>


-- 
ABDULGADER H. ABDULGADER ALSHARIF
MASTER STUDENT AT ISTANBUL KEMERBURGAZ UNIVERSITY
LIVE IN ISTANBUL-TURKEY
Mobile phone Viber & whatsapp no. 00905454567238.
Skype: [email protected]

Reply via email to