When running the power flow, it is the generator voltages that define the voltage magnitude set-points, so it is important to update them.
Ray > On Mar 18, 2019, at 9:47 PM, Jubeyer Rahman <[email protected]> wrote: > > Hi, > > I am running power flow iteratively as a part of an AC OPF algorithm, my > question is how important it's to update the generator voltages while I > update the bus voltages? Since the generators are connected to buses, > shouldn't it be sufficient to just update the bus voltages? > > Regards, > Jubeyer