Good morning, We are trying to evaluate MaxDB 7.6. We have to move our database from a Linux MaxDB 7.5.0.26 to a Windows XP MaxDB 7.6.0.10 server. To do so should create a full backup of our database from our old linux database, copy the files to our windows server and then create a database for recovering the datas. Here are our problems :
- When creating the database for recovery, the informations of the source database are well read BUT when processing a "0" error and a "communication error" occur. Anyway the database is created and in admin state. - When restoring the datas everything works fine. - When upgrading the system tables everything works fine. - When accessing to some tables (with no specific properties) the following error occurs Auto Commit: On, SQL Mode: Internal, Isolation Level: Committed General error;-3007 POS(1) Invalid sequence of DML and DDL statements SELECT * FROM "DBA"."TELTSAFFAIRE" It makes our database unusable. Are there known compatibility issues from 7.5.0.26 to 7.6.0.10 ? Are there known compatibility issues from Linux to Windows MaxDB Servers ? Is there something we should know about migrating from 7.5.x.x to 7.6.0.10 ? King regards. Xavier. -- MaxDB Discussion Mailing List For list archives: http://lists.mysql.com/maxdb To unsubscribe: http://lists.mysql.com/[EMAIL PROTECTED]