On Fri, 22 Apr 2011 13:16:36 +0800
<[email protected]> wrote:

> For the I2C adapter number to read EDID in MM platform is 0, add a new
> DMI match list to solve this issue.
> And, there are 3 I2C adapter numbers in Moorestown platform, using
> driver_data to denote which I2C adapter number is selected.
> 
> Patch against kernel-adaptation-mrst-2.6.37.6-8.1.

The patch looks fine but longer term this is a disaster in the making.
We need to get this coming from the firmware before every different
Oaktrail, Medfield and Moorestown device has to be put in a giant table
of 'guess the i²c' data.

Arjan - can we get something done about this before it becomes a
maintainability mess.

Alan
_______________________________________________
MeeGo-kernel mailing list
[email protected]
http://lists.meego.com/listinfo/meego-kernel

Reply via email to