On Dec 24, 2010, at 3:40 AM, ?zg?r ?nder KARAKILIN? wrote:
> So, should I do synchronization of fields when I use add-flux
> function ?

No, the Fourier transforms in add-flux automatically multiply the
fields by the phase for the correct times; no synchronization is needed.