What you are looking for are the command line switches described on page 13 of the Communicate Users Guide. Using these switches you can automate communicate including the loading of the machine settings. You need modify the target properties of the shortcut for Communicate to include the " -s" switch and the pathname of your machine setting (.sc) file.
i.e. C:\Sm9\SHARED\wcomm.exe -sC:\Sm9\Shared\Machine\fanuc0mb.sc ============================================= Fred Lauzus, CAM Programming Coordinator High Steel Structures, Incorporated mailto:[EMAIL PROTECTED] http://www.highsteel.com ============================================= -----Original Message----- From: Steve Buck [mailto:[EMAIL PROTECTED]] Sent: Wednesday, June 07, 2000 1:36 PM To: SmartCam user Group Subject: [mfg-smartcam] Comm default parms I installed Communicate and deleted all of the machines but one. It worked fine but I want it to default to the one machine every time. Is there a way to do this instead of loading the machine every time you execute the prog? Steve ATM ====================================================================== To find out more about this mailing list including how to unsubscribe, send the message "info mfg-smartcam" to [EMAIL PROTECTED] ====================================================================== ====================================================================== To find out more about this mailing list including how to unsubscribe, send the message "info mfg-smartcam" to [EMAIL PROTECTED] ======================================================================