Dave Wolfgang CNC Programmer/Supervisor www.hrindustries.net ----- Original Message ----- From: "Benz H. Babecki" <[EMAIL PROTECTED]> To: "Smartcam forum" <[EMAIL PROTECTED]> Sent: Tuesday, November 25, 2003 7:59 AM Subject: [mfg-smartcam] lathe thread control panel
> Hello, > I have a few questions about certain fields in the threading control panel that I was hoping I could get help with. > > 1> Nominal dia.: This is the basic major dia for external and basic minor dia for internal? YES > 2>"Root start D" and "Root end D": This I am presuming is the theoretical minor dia for external and theoretical major for internal threads? YES, USE THE LOOKUP BUTTON IN THE THREAD PANEL AFTER YOUR NOMINAL DIA. IS ENTERERD. AND THIS FIELD SHOULD BE ENTERERD AUTOMATICALLY. IF IT IS IN YOUR THREAD TABLE > 3> "Crest Start D": I've been using the same dia. that I put in the "Nominal dia." field. Is this correct or does this pertain to something else? THAT IS CORRECT, USE THE LOOKUP BUTTON IN THE THREAD PANEL AFTER YOUR NOMINAL DIA. IS ENTERERD. AND THIS FIELD SHOULD BE ENTERERD AUTOMATICALLY. > > Thanks for any and all help. > Benz > > Benz Babecki > Kingsbury, Inc. > 10385 Drummond Rd. > Philadelphia, PA 19154-3884 > Phone: 215-824-4985 > Fax: 215-824-4885 > mailto:[EMAIL PROTECTED] > http://www.kingsbury.com > > Kingsbury Inc > > ====================================================================== > To find out more about this mailing list including how to unsubscribe, > send the message "info mfg-smartcam" to [EMAIL PROTECTED] > ====================================================================== > ====================================================================== To find out more about this mailing list including how to unsubscribe, send the message "info mfg-smartcam" to [EMAIL PROTECTED] ======================================================================