Eric
JOE MEDEIROS wrote:
What I like about the 5-liner is to be able to see the "step" and "feed" info and especially the "time" info. I think maybe a 3-liner would be nice if possible. Maybe get rid of the "x=, y=, z=" info and maybe also the "machine=" info. Just my thought. Thanks.
Joe Medeiros Precision Plastics
916-689-5284
--------- Forwarded message ---------- From: "John Gent" <[EMAIL PROTECTED]> To: "'SmartCam Forum'" <[EMAIL PROTECTED]> Date: Thu, 22 Apr 2004 15:26:59 -0700 Subject: [mfg-smartcam] A Show Path tidbit Message-ID: <[EMAIL PROTECTED]>
Hi all,
Did you know that you can get a tiny (two lines tall) Show Path panel? It has to be done via the icon bar or a hot key, but is pretty slick.
Add these lines to your favorite icon .bar file.
BUTTON "Show Path" ICON "vwspth6" EVENT dialog "VIEWSHWPATH"
Or this line to the [Hotkeys] section of your favorite application.ini file.
SHIFT+F7=dialog "ViewShwPath"
Note that the difference is the "o" (ViewShwPath vs. ViewShowPath) as to the 2 line vs. the 5 line dialog.
Any thoughts on whether to make this the standard menu pick for v12? I've had the need for the 5 liner on rare occasions, but the 2 liner is the way to go ... that's my opinion anyway. What do you all think?
Cheers,
- John Gent
====================================================================== To find out more about this mailing list including how to unsubscribe, send the message "info mfg-smartcam" to [EMAIL PROTECTED] ======================================================================
________________________________________________________________ The best thing to hit the Internet in years - Juno SpeedBand! Surf the Web up to FIVE TIMES FASTER! Only $14.95/ month - visit www.juno.com to sign up today! ====================================================================== To find out more about this mailing list including how to unsubscribe, send the message "info mfg-smartcam" to [EMAIL PROTECTED] ======================================================================
-- Eric K. McKell, PE Assoc. Professor & Program Coordinator, MET Western Washington University Engineering Technology Department 516 High ST., ET 206 Bellingham, WA 98225-9086
office (360) 650-7931 fax (360) 650-4847
[EMAIL PROTECTED]
====================================================================== To find out more about this mailing list including how to unsubscribe, send the message "info mfg-smartcam" to [EMAIL PROTECTED] ======================================================================