For the record:

mikeb@ picked this up in "PFSYNC - pf.conf best practice"-thread.

On 10/31/2011 12:48 PM, Henning Brauer wrote:
* Maxim Bourmistrov<m...@alumni.chalmers.se>  [2011-10-26 08:23]:
I have a CARP setup in failover.
Is there any reason for ESTABLISHED states on the failover node to
have double expiration time?
Eg. on master the exp. time is 5h (set optimisation aggressive),
while on slave it is 10h.
wow. I have never noticed that. That is a bug.

Is there any way to control it?
find&  fix the bug :)

Reply via email to