I have mfii too:
dmesg | grep mfii:

mfii0 at pci11 dev 0 function 0 "Symbios Logic MegaRAID SAS2208" rev 0x05:
msi
mfii0: "LSI MegaRAID SAS 9271-8i", firmware 23.28.0-0010, 1024MB cache
scsibus1 at mfii0: 64 targets
scsibus2 at mfii0: 256 targets

> On 8.9.2019. 18:19, Luke Small wrote:
> > It doesn't work for me on the
> > ftp.hostserver.de/archive/2019-08-29-0105/amd64/
> > bsd.rd!
>
>
> Hi,
>
> do you maybe have mfii on that box ?
>
> I'm having same problem as Mischa and i have mfii. with bsd.rd fsck
> stops with this command
>
> Which disk is the root disk? ('?' for details) [sd0] sd0
> Checking root filesystem (fsck -fp /dev/sd0a)...
>
> On other boxes without mfii bsd.rd and sysupgrade works just fine..
>
> between 27.08 and 29.8 i saw this commit
>
> Changes by:   d...@cvs.openbsd.org    2019/08/27 22:55:51
>
> Modified files:
>       sys/dev/pci    : mfii.c
>
> Log message:
> implement a DV_POWERDOWN handler to flush cache and shutdown the controller
>
> this has been in snaps for the last week without issue, and has
> been running in production on a bunch of my boxes for a week before
> that, also without issue.
>
>
>

Reply via email to