On Fri, Jun 05, 2020 at 10:52:38AM +0200, Marek Benc wrote:

> There's been some changes in the OpenBSD port of smartmontools,
> tools for working with S.M.A.R.T diagnostic of hard drives and SSDs,
> the platform-specific code was modernized, so it would be quite useful
> if people could test these changes out to make sure they work on all
> systems, I tested them on a macppc system with an ATA drive.
> 
> The developer doesn't currently have access to a physical system
> with OpenBSD running on it, so they wrote the changes in a virtual
> machine.
> 
> You can find the changes here:
> https://github.com/smartmontools/smartmontools/pull/56
> 

Seems to work fine here:

calvin$ uname -a
OpenBSD calvin.int.osk.am 6.7 GENERIC.MP#2 amd64
calvin$ sysctl hw | egrep '(model|vendor|product|version)'
hw.model=Intel(R) Pentium(R) CPU G3450 @ 3.40GHz
hw.vendor=Shuttle Inc.
hw.product=DS81L
hw.version=V1.0
calvin$ doas ./smartctl -a -d ata /dev/rsd0c
smartctl 7.2 (build date Jun  6 2020) [OpenBSD 6.7 amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Samsung based SSDs
Device Model:     Samsung SSD 840 EVO 120GB
Serial Number:    S1D5NSBDB26732X
LU WWN Device Id: 5 002538 8a00f2d01
Firmware Version: EXT0DB6Q
User Capacity:    120,034,123,776 bytes [120 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
TRIM Command:     Available
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Sat Jun  6 10:41:51 2020 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                ( 4200) seconds.
Offline data collection
capabilities:                    (0x53) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        No Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  70) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  5 Reallocated_Sector_Ct   0x0033   100   100   010    Pre-fail  Always       
-       0
  9 Power_On_Hours          0x0032   087   087   000    Old_age   Always       
-       64013
 12 Power_Cycle_Count       0x0032   099   099   000    Old_age   Always       
-       545
177 Wear_Leveling_Count     0x0013   098   098   000    Pre-fail  Always       
-       24
179 Used_Rsvd_Blk_Cnt_Tot   0x0013   100   100   010    Pre-fail  Always       
-       0
181 Program_Fail_Cnt_Total  0x0032   100   100   010    Old_age   Always       
-       0
182 Erase_Fail_Count_Total  0x0032   100   100   010    Old_age   Always       
-       0
183 Runtime_Bad_Block       0x0013   100   100   010    Pre-fail  Always       
-       0
187 Uncorrectable_Error_Cnt 0x0032   100   100   000    Old_age   Always       
-       0
190 Airflow_Temperature_Cel 0x0032   067   053   000    Old_age   Always       
-       33
195 ECC_Error_Rate          0x001a   200   200   000    Old_age   Always       
-       0
199 CRC_Error_Count         0x003e   099   099   000    Old_age   Always       
-       4
235 POR_Recovery_Count      0x0012   099   099   000    Old_age   Always       
-       47
241 Total_LBAs_Written      0x0032   099   099   000    Old_age   Always       
-       13444727948

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.