Le jeudi 14 janvier 2021 à 15:47 +0100, Marcus MERIGHI a écrit : > Hello, > > [email protected] (Bastien Durel), 2021.01.14 (Thu) 10:20 (CET): > > I have a router connected via a serial port to another machine > > (which > > is usually powered off), wich fails to boot until I connect and > > validate the boot> prompt > > > > I configured my boot.conf as it follows : > > > > # cat > > /etc/boot.conf > > set timeout 10 > > set tty com0 > > I usually have > > stty com0 115200 > set tty com0 > set timeout 2 > > and the machines boot automagically... > > Marcus > Actually, it looks like the automagic boot depends on the status of the attached computer : when it runs, the router boots automagically, and when it does not, then the boot waits until I press enter (after booting it, obviously)