Josh,
If you are metering the current to the DPR and the needle is bouncing, then
the O2 is usually good.  A steady reading indicates a bad O2 - usually.

Sounds to me like you have a vaccuum leak.  Although I could be wrong.
Never hurts to check though.

Rich Blake
88GTi16v

> -----Original Message-----
> From: [email protected]
> [mailto:[email protected]]On Behalf Of
> [email protected]
> Sent: Thursday, March 27, 2003 8:21 PM
> To: [email protected]
> Subject: [a2-16v-list] car runs better once you unplug the DPR??? WTF???
>
>
> motronic..... high idle untill you unplug the DPR then
> it drops to about normal
>
> Ok, so the full throtle switch takes the O2 out of the
> equation correct?
> I set the DPR voltage to set it to 2.5, then the next
> week it got funky on me. I think maybe it is rich and
> killed the O2?
>
> It started acting funky at the track after I shut it
> off and restarted it.
>
> Then I drove it home and it would only run 'right' if I
> had it floored.....part throtle was all ****ed up.
>
> I'm going to install a new O2 and reset the mixture and
> see if that fixes it. Def NOT going 2.5 this time,
> prolly go 4.....
> _______________________________________________
> a2-16v-list mailing list
> [email protected]
> http://mail.a2-16v.com/mailman/listinfo/a2-16v-list
> For list archives, see listinfo link above.
>

Reply via email to