On Tue, Jan 25, 2011 at 3:00 PM, John Hurst <[email protected]> wrote:
> Make sure your up/down-stream settings are correct. ACL scanning stops as
> soon as a user group matches, which may happen before your explicit settings.
> Or even worse, fall through to the end, with no explicit setting.
>
> Check what your HelpOnAccessControlLists page says, particularly section 5.
>
> From what you say, I think you need to add
>
> acl_rights_after = u"All:read" (or even u"All:", i.e., no rights)
>
> to make sure that "All" is not overlooked.
I gave that a try just to be sure and it didn't fix the problem. For
the record it now says:
acl_enabled = 1
acl_rights_default = u"All:read"
acl_rights_before = u"stefan:read,write,delete,revert,admin
DanielDiniz:read,write,delete,revert,admin
RichardJones:read,write,delete,revert,admin"
acl_rights_after = u"All:read"
Even better, I've just discovered that it's just the one page (as far
as I can tell) that is editable. The rest of the wiki is protected.
The wiki is at http://www.roundup-tracker.org/cgi-bin/moin.cgi/FrontPage
... the TranslationStatus page is editable by Known, but they can't
edit anything else...
Richard
------------------------------------------------------------------------------