Hi all,

I am trying to do numerical frequency calculation with CASPT2 for a
symmetric molecule, so I need to turn symmetry off.
But strangely enough, "NOSYM" option does not work: the following
input

"geometry={,
NOSYM
ANGSTROM
C,0,0.6729491965,-1.8215930149,0.0000000000;
C,0,-0.6729491965,-1.8215930149,0.0000000000;
etc."
gives me
"cannot find default basis VDZ                 for atomic number   102"
Apparently, MOLPRO does not recognize this option, but instead
understands it as Nobelium atom input.

Is it a bug or I am just doing something wrong?


-- 
Best regards,
 Qadir Timerghazin              mailto:[EMAIL PROTECTED]
                                mailto:[EMAIL PROTECTED]

****************************************************************************
Qadir K. Timerghazin                 * Kadyr K. Timergazine
Centre for Research                  * Centre de Recherche en
in Molecular Modeling                * Modйlisation Molйculaire
                                     *
Concordia University                 * Universitй Concordia
1455 De Maisonneuve Blvd St. West,   * 1455 Bvd De Maisonneuve Ouest
Montreal, Quebec,                    * Montrйal, Quйbec,
CANADA H3G 1M8                       * CANADA H3G 1M8
                                     *
Room: 1034-1                         * Salle: 1034-1
Phone: (514) 848 3360                * Tel: (514) 848 3360
****************************************************************************


Reply via email to