Hi! I had the same problem in anon calculations and the shift keyword
worked for me. I remember I spend a lot of time though, since I tried
shift,N where N was 1, 2, 3, etc; sometimes I had to use 5. And the
calculations passed many cycles before they converged successfully with
even reduced convergence criteria. In your case it might work better,
since my calculations were on dipole-bound anions which are actually
sometimes a trouble even for Hartree-Fock . This question has been asked many times, here is a short but a useful explanation: http://www.molpro.net/molpro-user/archive/all/msg00068.html Regards, Kadir Matt Thompson wrote: On Fri, 2004-07-09 at 09:31, Stavros Kardahakis wrote:Dear MOLPRO users, |