Hello,
I noticed that "no_comp_alerts" does not work in the following configuration:
watch HOSTGROUP
service SVC
interval 5m
monitor MONITOR
period failure: wd{mon-fri} hr{8-18}
alert wh-file.alert
period up: wd{mon-sun}
no_comp_alerts
upalert wh-file.alert
Looking in the code and logs, I found that
_no_comp_alerts_upalert_sent is never reset to zero when no alert
script is called. So upalerts are sent only once (at startup or
reset).
The following patch against mon 1.2.0 seems to correct this, by
forcing the reset as soon as possible:
--- mon.orig 2007-07-23 17:37:10.988935200 +0200
+++ mon 2007-07-23 17:38:34.916224800 +0200
@@ -666,6 +666,18 @@
my $pref = \%{$sref->{"periods"}->{$periodlabel}};
+ #
+ # Reset no_comp_alerts counter if ALERT
+ #
+ if ($pref->{"no_comp_alerts"} &&
+ $pref->{"_no_comp_alerts_upalert_sent"} > 0 &&
+ !($flags & ($FL_UPALERT|$FL_ACKALERT|$FL_DISABLEALERT|$FL_ENABLEALER
+T))) {
+ syslog('debug',"$group/$service/$periodlabel: ALERT, no_comp_alerts
+reset");
+ $pref->{"_no_comp_alerts_upalert_sent"} = 0;
+ }
+
#
# skip upalerts/ackalerts not paired with down alerts
# disable by setting "no_comp_alerts" in period section
Does it look reasonable ?
Thanks,
--
Nicolas
_______________________________________________
mon mailing list
[email protected]
http://linux.kernel.org/mailman/listinfo/mon