Sorry - I was copying and pasting from an alert email. The ports
"do" match up in my monit script
Here's a real example:
#8002
check process mongrel_rails_8002 with pidfile /var/run/mongrel/mongrel.8002.pid
group mongrel
start program = "/usr/local/bin/ruby /usr/local/bin/mongrel_rails
start -d -e production -a 127.0.0.1 -c /opt/rails/radius --user
mongrel --group mongrel -p 8002 -P /var/run/mongrel/mongrel.8002.pid
-l /var/log/mongrel/mongrel.8002.log"
stop program = "/usr/local/bin/ruby /usr/local/bin/mongrel_rails
stop -P /var/run/mongrel/mongrel.8002.pid"
if totalmem > 100.0 MB for 5 cycles then restart
if failed host 127.0.0.1 port 8002 protocol http
with timeout 10 seconds
then restart
On Wed, Mar 26, 2008 at 6:27 PM, John Weir <[EMAIL PROTECTED]> wrote:
> well, something doesn't seem right:
>
> -> mongrel_rails_8001' failed protocol test [HTTP] at
>
> INET[127.0.0.1:8018]
>
> ^
> ^^^^^^^^^^^^
>
> 127.0.0.1:8018 <- port 8018? or do you want port 8001?
>
> also i leave the host parameter out of the monit config.
>
> if failed port 8015 protocol http
> with timeout 20 seconds
> then restart
>
>
>
> On Mar 26, 2008, at 5:53 PM, Michael Engelhart wrote:
>
> > Does anyone have any tips for checking to see if the mongrel instance
> > is responding to HTTP? I just tried doing this:
> >
> > if failed host 127.0.0.1 port 8001 protocol http
> > with timeout 10 seconds
> > then restart
> >
> > but when I have that code in my monit script it gives me this error:
> > mongrel_rails_8001' failed protocol test [HTTP] at
> > INET[127.0.0.1:8018] via TCP
> >
> >
> > Thanks for any tips.
> >
> > Mike
>
>
> _______________________________________________
> Mongrel-users mailing list
> [email protected]
> http://rubyforge.org/mailman/listinfo/mongrel-users
>
_______________________________________________