What MQMD format are you using?

If you have MQMD_FORMAT = MQCICS then you must include the MQCIH structure
ahead of your data. If you have MQSTR then you must not include the MQCIH
structure.

As a rule, you should use MQCICS and include the MQCIH, especially if you
are invoking a DB2 program. It is through a field in the MQCIH that you can
change the TRANID of the bridge task from the default of CKBP to something
that better suits your RCT definitions.

The message you are getting suggests to me that you do have a format of
MQCICS but you do not have a MQCIH structure included.




                           Jason Cornell               To:     [EMAIL PROTECTED]
                           <Jason_Cornell@LABCOR       cc:
                           P.COM>                      Subject:       CICS Bridge 
(CKBR)
                           Sent by: MQSeries
                           List
                           <[EMAIL PROTECTED]
                           .AT>


                           10/01/2002 05:03 PM
                           Please respond to
                           MQSeries List






Currently, we are attempting to utilize the CICS Bridge to pass data to the
COMMAREA of a screenless CICS COBOL program that does a DB2 select.  The
comm area in the linakage section is as follows:

       LINKAGE SECTION.
       01  DFHCOMMAREA.
            05  HOLD-YEAR-PREFIXO         PIC X.
            05  HOLD-JULIAN-DATEO         PIC X(3).
            05  HOLD-ACCESSION-CODEO      PIC X(3).
            05  HOLD-SEQUENCEO            PIC X(4).
            05  HOLD-SUFFIXO              PIC X.
            05  HOLD-ORDERING-ACCT-NUM0   PIC X(8).

       PROCEDURE DIVISION USING DFHCOMMAREA.

When putting the following message to the queue:

TPGMTR310A00F4014726 (with 8 trailing blanks for the return values)

this message appears in the spool for our CICS test region on the OS/390.

CSQC700I CKBR 0008674 IBM MQSeries for OS/390 V5.2 - CICS bridge.
Copyright(c) 1
CSQC705E CKBR 0008674 Parameter at offset 178 in input string is invalid
CSQC700I CKBR 0008675 IBM MQSeries for OS/390 V5.2 - CICS bridge.
Copyright(c) 1
CSQC705E CKBR 0008675 Parameter at offset 178 in input string is invalid

As I understand the first eight bytes in the message TPGMTR31 instructs the
CICS bridge to perform a link to the program passing the following bytes.
Any suggestions?

Jason

Instructions for managing your mailing list subscription are provided in
the Listserv General Users Guide available at http://www.lsoft.com
Archive: http://vm.akh-wien.ac.at/MQSeries.archive

Instructions for managing your mailing list subscription are provided in
the Listserv General Users Guide available at http://www.lsoft.com
Archive: http://vm.akh-wien.ac.at/MQSeries.archive

Reply via email to