We are getting errors on a
channel retry, which happens on QMGR startup. It connects two os/390 lpars.
Both qmgrs are recycled in the
early morning around the same time, so it is natural that often one side is not
ready for the other side to connect. That is when the channel retry seems to
start.
Here are the error messages
-
+CSQX202E +QWP1 CSQXRCTL Connection or remote listener unavailable, 770 channel QWP1/QWT1, connection XXXXXXXX (999.999.999.999) TRPTYPE=TCP RC=00000468 +CSQX599E +QWP1 CSQXRCTL Channel QWP1/QWT1 ended abnormally
CSQX251I +QWP1 CSQXSTRL Listener started, TRPTYPE=TCP INDISP=QMGR CSQX218E +QWP1 CSQXLSTT Listener unable to bind to port 1414 address .0.0.0, TRPTYPE=TCP INDISP=QMGR, RC=0000045B CSQX234I +QWP1 CSQXLSTT Listener stopped, TRPTYPE=TCP INDISP=QMGR CSQX208E +QWP1 CSQXRESP Error receiving data, 775 channel ????, connection XXXXXXXX (999.999.999.999) (queue manager ????) TRPTYPE=TCP RC=00000480 First we get many of these CSQX251, 218, 234, 208E messages. Then we get the CSQX251, 218 and 234 messages without the 208 message. Then after an hour, we get the 208 message with the others.. I'm assuming that the Long Retry is kicking in. When we look at the IP address we get:H:\>nslookup 999.999.999.999
Server: DDDDDDDD.net (dsn server) Address: 888.888.888.888 (dns server IP) Name: XXXXXXXXX..net (lpar name
(#1)
Address: 999.999.999.999 (IP address) H:\>nslookup YYYYYYYYY (other dns name for lpar) Server: DDDDDDDD.net (dns server) Address: 888.888.888.888 (dns server IP) Name: XXXXXXXXXX.NET (lpar name
(#1)
Address: 999.999.999.999 (IP address) Aliases: YYYYYYYY.NET (other dns name for lpar) I'm sorry I had to replace the names and
addresses for reasons of security.
What it looks like is that we have two
different names for the same lpar, one is the primary (XXXXXXXX) and one is an
alias (YYYYYYYYY). Actually the primary name is new, and we had previously used
the alias name(which used to be the one and only name).
Could that be a problem
in channel retry handshaking??
This e-mail and any files transmitted with it, are confidential to National Grid and are intended solely for the use of the individual or entity to whom they are addressed. If you have received this e-mail in error, please contact the National Grid USA Enterprise Support Center on 508-389-3375 or 315-428-6360. |
Title: Message
- Failover in a Hub-spoke model??? Heggie, Peter