Dave,
Yes,
you need to get hold of your client application programmers (by the
throat!). What they've done is to write an application that does an
MQCONN, and MQPUT and/or MQGET, then an MQDISC. They need to rewrite it so
that they connect once when needed and disconnect only when shutting down their
end.
ҿ�
Bob Juch
Citigroup
MQ Mainframe Support
Team
Weehawken, NJ
201-974-2147
mailto:[EMAIL PROTECTED]
-----Original Message-----
From: MQSeries List [mailto:[EMAIL PROTECTED]On Behalf Of Williams, Dave (Systems Management)
Sent: Thursday, October 28, 2004 11:54 AM
To: [EMAIL PROTECTED]
Subject: MQ MessagesWe're receiving an inordinate amount of console messages from MQ regarding a server connection we have -
09.47.52 STC04052 +CSQX500I _ CSQXRESP Channel CLIENT.TO.MQPX started
09.47.52 STC04052 +CSQX501I _ CSQXRESP Channel CLIENT.TO.MQPX is no longer active
These are repeating every two or three seconds and making the operators crazy - I don't want to suppress messages - Perhaps I have something set incorrectly that's causing this condition to occur? Has anyone else had this issue?
Thanks,
Dave