> -----Original Message----- > From: [EMAIL PROTECTED] > [mailto:[EMAIL PROTECTED] On Behalf Of MuQ'>| > Sent: Monday, June 07, 2004 10:07 PM > To: [EMAIL PROTECTED] > Subject: [mrtg] can't get traffice from sub-interface of router >
[snippy] > SNMP Error: > Received SNMP response with error code > error status: noSuchName > index 1 (OID: 1.3.6.1.2.1.2.2.1.10.18) SNMPv1_Session > (remote host: "192.168.0.1" [192.168.0.1].161) > community: "public" > request ID: 1030702553 > PDU bufsize: 8000 bytes > timeout: 2s > retries: 5 > backoff: 1) > SNMPGET Problem for ifInOctets.18 ifOutOctets.18 sysUptime > sysName on [EMAIL PROTECTED]::::::v4only We are monitoring an atm interface on a subinterface aal5-layer, looks like a similar setup anyway: https://openfire.coloradocollege.edu/cgi-bin/routers2.cgi?uopts=t&rtr=loo_ 7206.cfg Do you have the full pipe, or do you have just a chunk of it you want to monitor? We've only got a piece of the line though... You might want to check out the reply from the device, noSuchName, you should try adding a .0 or .1 to the end, or just walkin the oid you've got. Funny question, but did you try cfgmaker on the device? The program walked a 7206VXR here, and it did report the correct interfaces, and the correct sub interfaces right into a handy config file. Dave -- Unsubscribe mailto:[EMAIL PROTECTED] Archive http://www.ee.ethz.ch/~slist/mrtg FAQ http://faq.mrtg.org Homepage http://www.mrtg.org WebAdmin http://www.ee.ethz.ch/~slist/lsg2.cgi