It does have IMPORTS:
IMPORTS
org, dod, internet, directory, mgmt, experimental, private,
enterprises
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
DisplayString
FROM RFC-1213;
The MIB is supplied by the vendor for the power system. Is there a
possible bug in FreeBSD 8.x? This configuration works on previous
versions of FreeBSD 7.x.
----
Paul - Network Operations Specialist
On Feb 8, 2011, at 5:39 AM, Daniel McDonald wrote:
> On 2/8/11 7:15 AM, "Paul Rising" <[email protected]> wrote:
>
>> I am receiving the following SNMP variable errors:
>>
>> Unknown SNMP var PB1-CB1-Current.0
>> at /usr/local/bin/mrtg line 2343
>> Unknown SNMP var PB1-Current-Ground-Panelboard.0
>> at /usr/local/bin/mrtg line 2343
>> 2011-02-04 03:45:00: WARNING: Expected a number but got '166 days,
>> 2:42:04'
>> 2011-02-04 03:45:00: WARNING: Expected a number but got 'Not Set'
>>
>>
>> Below is a portion of the mrtg configuration file:
>> ## Global Config Options
>> WorkDir: /home/mrtg/PDU_CABS
>> LoadMibs: /usr/local/share/snmp/mibs/BCMSplus-sub.mib
>
> Does the /usr/local/share/snmp/mibs/BCMSplus-sub.mib file have any
> IMPORTS
> lines? You may need to load other pre-requisite mibs in order to
> parse that
> file properly.
>
> --
> Daniel J McDonald, CCIE # 2495, CISSP # 78281
>
> _______________________________________________
> mrtg mailing list
> [email protected]
> https://lists.oetiker.ch/cgi-bin/listinfo/mrtg
_______________________________________________
mrtg mailing list
[email protected]
https://lists.oetiker.ch/cgi-bin/listinfo/mrtg