Dear Navid,

It's difficult to say without seeing actual data, but one thing to remember is that there is NO evaluation of the intercept for the stretching method, so if your wave packets are not exactly at the time delta on the two sides (could be a clock error, for example), this is not taken into account for stretching.

Best regards,

Thomas

Le 14/09/2020 à 16:49, navid.sirous a écrit :
Dear MSNoise users,

Although my cross-correlation functions (CCF) are relatively
symmetrical, they have different positive and negative lag-time (left
and right side). When I used the MSNoise for the stretching method, my
results for different dtt_sides (both sides, right side, and left side)
are exactly the same, while they should have different results. So, do
you know how can I fix this problem?

Sincerely,

Navid
_______________________________________________
MSNoise mailing list
[email protected]
http://mailman-as.oma.be/mailman/listinfo/msnoise
_______________________________________________
MSNoise mailing list
[email protected]
http://mailman-as.oma.be/mailman/listinfo/msnoise

Reply via email to