On Tuesday 01 March 2005 21:18, Ludovic Rousseau wrote:
> Le Tuesday 01 March 2005 à 15:26:38, Serge Koganovitsch a écrit:
> > When using 'pcscd -f' I get a SIGSEGV in get_ccid_usb_interface() whenever 
> > I remove the CCID reader. That's why I had to restart pcscd ...
> 
> This is a know bug corrected (I hope) in the CVS version of the CCID
> driver.  I think the bug is in libusb since the crash occurs in one of
> its functions.
> 
> You can either use the CVS version of the CCID driver or downgrade your
> libusb library.

Hi,

I am now using the CVS version of the CCID driver and I can confirm that this 
bug
has been solved !

Another interesting thing, the SCR 3310 CCID performance is now on par with 
other CCID
readers. This reader with the 0.9.2 version was 3 times slower ! What has 
changed that 
could explain this ?

Best regards,

Serge

_______________________________________________
Muscle mailing list
Muscle@lists.musclecard.com
http://lists.drizzle.com/mailman/listinfo/muscle

Reply via email to