-----BEGIN PGP SIGNED MESSAGE----- 2.5/40Gb.. only 6.25% usage.. you sure you needed to spend the money upgrading from your OC192? :)
Steve On Sun, 30 May 2004, Peter Lothberg wrote: > > RP/0/RP0/CPU0:sl-bb-stk#sh int pos 0/1/0/0 > POS0/1/0/0 is up, line protocol is up > Hardware is Packet over SONET > Description: To sl-bbh-sj POS0/2/0/0 OC768 to SL-BB-SJC > Internet address is 144.232.8.30/30 > MTU 4474 bytes, BW 39813120 Kbit > reliability 255/255, txload 11/255, rxload 16/255 > Encapsulation HDLC, crc 32, controller loopback not set, keepalive set (10 sec) > Last clearing of "show interface" counters 00:54:50 > 30 second input rate 2556047000 bits/sec, 601233 packets/sec > 30 second output rate 1778638000 bits/sec, 511869 packets/sec > 1666954975 packets input, 858714019017 bytes, 1 total input drops > 0 drops for unrecognized upper-level protocol > Received 0 broadcast packets, 0 multicast packets > 0 runts, 0 giants, 0 throttles, 0 parity > 1 input errors, 1 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort > 1493380753 packets output, 636636581471 bytes, 0 total output drops > Output 0 broadcast packets, 0 multicast packets > 0 output errors, 0 underruns, 0 applique, 0 resets > 0 output buffer failures, 0 output buffers swapped out > 0 carrier transitions > > RP/0/RP0/CPU0:sl-bb-stk#sh control sonet 0/1/0/0 > Port SONET0/1/0/0: > > Status: Up > > Loopback: None > > SECTION > LOF = 0 LOS = 0 BIP(B1) = 1 > LINE > AIS = 0 RDI = 0 FEBE = 0 BIP(B2) = 1 > PATH > AIS = 0 RDI = 0 FEBE = 0 BIP(B3) = 1 > LOP = 0 NEWPTR = 0 PSE = 0 NSE = 0 > > Line triggers delayed 20 msDetected Alarms: None > Asserted Alarms: None > Mask for Detected->Asserted: None > Detected Alerts: None > Reported Alerts: None > Mask for Detected->Reported: None > Alarm reporting enabled for: SLOS SLOF SF_BER PLOP > Alert reporting enabled for: B1-TCA B2-TCA B3-TCA > > Framing: SONET > SPE Scrambling: Enabled > C2 State: Stable C2_rx = 0x16 (22) C2_tx = 0x16 (22) / Scrambling Derived > S1S0(tx): 0x0 / Framing Derived > > PATH TRACE BUFFER : STABLE > Remote hostname : sl-bb-sj > Remote interface: POS0_2_0_0 > Remote IP addr : 144.232.8.29 > Remote Rx(K1/K2): 00/00 Remote Tx(K1/K2): 00/00 > > BER thresholds: SF = 10e-3 SD = 10e-6 > TCA thresholds: B1 = 10e-6 B2 = 10e-6 B3 = 10e-6 > > Optics type: VSR2000-3R2 (2km) > Clock source: line (actual) line (configured) > > Optical Power Monitoring (accuracy: +/- 1dB) > Rx power = 1562.3280 mW, 31.9 dBm > Tx power = 15.4640 mW, 11.9 dBm > Tx laser current bias = 96.2 mA > > -----BEGIN PGP SIGNATURE----- Version: GnuPG v1.2.1 (GNU/Linux) iQB1AwUBQLvA+1wK6AZ3LKU5AQG+GgL/RzImlvNRyFxp4P8S0ImK+fe2CEgtWLUT dM5D5+HkFkaM0mtW3x/zhpo0Hm9UBOe5/ATe/sfSvGA1iOYuZzvOVyF4caZG/D0C 38ilqTuhvtfzcVJRLD53kFL2L+zJvJe2 =rBvW -----END PGP SIGNATURE-----