In a situation where a link fails and the VC needs to be rerouted. The VC path has allready been setup.
Thanx Paul On Tue, 30 Nov 2004, Dan Armstrong wrote: >That depends on if the SVC was torn down due to a broken link, or if the >switch is just coming online, or if it was rerouted around congestion, and a >million other tuneable factors. > >In our network, SVC (SPVCs) get rerouted at near sonet speeds, although that's >not very scientific. > >Dan. > > > > >On Tuesday 30 November 2004 16:25, Paul Khavkine wrote: >> Hi folks. >> >> >> Does anyone know the time it takes or should take for an SVC to be >> rerouted in a small 4-6 switch ATM network running PNNI ? >> >> Is it part of the ATM spec or does it depend on the switch manufacturer ? >> >> >> >> Thanx >> Paul >> >> ************************************************ >> Paul Khavkine >> Network Administrator >> DISTRIBUTEL Communications. >> 740 Notre Dame West, Suite 1135 >> Montreal, Quebec, Canada, H3C 3X6 >> 1-514-877-5505 x 263 >> http://www.distributel.net >> ************************************************ > > ************************************************ Paul Khavkine Network Administrator DISTRIBUTEL Communications. 740 Notre Dame West, Suite 1135 Montreal, Quebec, Canada, H3C 3X6 1-514-877-5505 x 263 http://www.distributel.net ************************************************